Filter Results By:

Products

Applications

Manufacturers

Voltage Transformer

a type of intrument transformer enabling secondary connected metering.


Showing results: 151 - 165 of 340 items found.

  • HV AC Voltage Test Systems

    Fivestar HV Testing Equipment Co., Ltd.

    FSHV offers three different types of AC voltage test systems, the conventional type is AC test transformer design, mainly for testing objects of medium & low capacitance products, particularly for tests requiring stable voltage even if the load changes under voltage (corona, wet & pollution tests) or when the load is inductive (like inductive voltage transformers). Another is AC resonant test systems, according to series resonance circuit XL=XC (2πfL=1/2πfC), by setting F frequency of power supply or L inductance of reactor, generate a pure sinusoidal waveform of the test voltage, and the required input power is only 1/Q. Variable frequency type operates in a frequency range from 20Hz to 300Hz, ideal for field commissioning test of power cables and GIS/GIL. Variable inductance type outputs continuous AC voltage of power frequency (50/60Hz), mainly for factory testing of high and ultra-high voltage cables, power transformers, GIS, etc.

  • Multifunction Substation Test Set

    STS 4000 - Altanova Group

    STS 4000 is a multifunction substation maintenance & commissioning test system for current, voltage and power transformers, designed to perform primary tests requested in substations commissioning. It allows to perform accurate tests on CTs, VTs, PTs and ground grid.

  • Multifunction Substation Test Set

    STS 5000 - Altanova Group

    STS 5000 is a multifunction substation maintenance & commissioning test system for current, voltage and power transformers designed to perform primary tests requested in substations commissioning. It allows to perform accurate tests on CTs, VTs, PTs and ground grid.

  • Turns Ratio Testers

    TRT Advanced Series - IBEKO Power AB

    TRT Advanced series is the newest DV Power solution for transformer turns ratio measurement. Besides its main application, each turns ratio tester from this series also measures transformer excitation current and phase shift. Furthermore, all models perform automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. They have a built-in true three-phase power source. For that reason, they can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 500 V AC, depending on the model. With the highest test voltage 500 V AC, TRT500 provides the most accurate turns ratio testing of power transformers used in power generation and transmission. The output test voltage of TRT500 can be boosted to 5 kV AC using the external CVT20 extension transformer. This application is specially designed for testing turns ratio of capacitive voltage transformers. The other three models, TRT400, TRT250, and TRT100 can output up to 400 V, 250 V, and 170 V respectively. The low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT500 is equipped with a large 10.1” graphical touch screen display. Other models, (TRT400, TRT250, TRT100) have 7” graphical touch screen display. Besides making the interface much more user-friendly compared to older turns ratio testers, it also brings certain options that were previously available only with DV-Win software. The most important are test templates and automatic test mode. Users can simply create test templates, store them in the instrument’s memory, and load when in the field with just a few clicks.This turns ratio test set, as well as all other DV Power turns ratio testers, has a built-in tap changer control unit. It enables remote control of an on-load tap changer (OLTC) directly from the instrument. In order to make the most out of this feature, the instrument can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time. Automatic test mode minimizes human errors, which makes the measurement more reliable.

  • Transformer Turns Ratio Testers

    IBEKO Power AB

    Transformer turns ratio testers from TRT series are DV Power instruments mainly designed for the measurement of power transformer turns ratio. Also, they measure transformer excitation current and phase shift. Special tests, such as automatic vector group detection and magnetic balance, can be performed on three-phase transformers and three-phase autotransformers.All models, except TRT03 series, have a built-in true three-phase power source, which is necessary for testing turns ratio of transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.DV Power turns ratio testers can output various test voltages for different applications. From the extremely low test voltage of 1 V AC that enables turns ratio verification of the majority of current transformers, up to the highest test voltage of 500 V AC that provides the most accurate turns ratio testing of power transformers used in power generation and transmission. By using the external booster, test voltage increases up to 5 kV AC in order to successfully test capacitive voltage transformers.All DV Power turns ratio testers have a built-in tap changer control unit. Because of that, it is possible to control the on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, the instrument and included DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option significantly facilitates and shortens the turns ratio testing time.TRT turns ratio testers use the same set of cables as three-phase winding ohmmeter & tap changer analyzers from the TWA series. Consequently, it enables one-time cable setup for performing eight tests:turns ratioexcitation currentphase anglemagnetic balancevector group detectionwinding resistanceon-load tap changer DVtestand demagnetization.

  • AC/DC Withstanding Voltage& Resistance Tester

    TH9201 - Changzhou Tonghui Electronic Co., Ltd.

    TH9201 AC/DC withstanding voltage & insulation tester is a kind of Hipot Tester. Due to simple and compact structure, mature technique, brand new structure and operating interface, the operation becomes more convenient, and more practical functions are included as well. TH9201S can be widely applied in transformer, device, component especially for winding safety inspection.Withstanding voltage test

  • AC/DC Withstanding Voltage& Resistance Tester

    TH9201B - Changzhou Tonghui Electronic Co., Ltd.

    TH9201 AC/DC withstanding voltage & insulation tester is a kind of Hipot Tester. Due to simple and compact structure, mature technique, brand new structure and operating interface, the operation becomes more convenient, and more practical functions are included as well. TH9201S can be widely applied in transformer, device, component especially for winding safety inspection.Withstanding voltage test

  • Instrument Transformer

    NEO TELE-TRONIX PVT. LTD

    Our company has achieved a reputed niche in international market by manufacturing and exporting a great range of Instrument Transformer. Widely used in electrical, power generation and engineering sector for transforming voltage or current level, this equipment is in accordance with industry standards. Manufactured using excellent grade raw materials sourced from reputed vendor, Instrument Transformer is offered to clients in different technical specifications. We stringently test this instrument on varied standard parameters.

  • AC Voltage Test Systems

    HIGHVOLT Prüftechnik Dresden GmbH

    AC resonant test system is used for factory testing of middle, high and ultra-high voltage cables, capacitors, generators, motors, power transformers and gas-insulated switchgears.

  • Oil Immersed Test Transformer

    SG-YD - Wuhan Sangao Electrical Test Installations Limit Co.

    AC and DC test oil immersed transformer.Traditional oil immersed test transformer is used to do power frequency withstand voltage and DC current withstand voltage test for variety kinds of high voltage electric device, insulating material.YD series oil transformer, also known as test booster, which test insulation strength under specified voltage for various electric products, components, insulation materials. It can test products insulation level, find insulation defect and judge overvoltage ability. It is widely used in power station, power supply and distribution system and research institute.

  • Tap Adapter

    Techimp HQ S.r.L

    Techimp Voltage Tap Adapter is gender changer which allows the user to connect to the test tap (sometimes called power factor tap) of high voltage transformer bushings.While keeping the test tap well below the safety voltage level required by the manufacturer, the Tap Adapter lets the user to drain high frequency PD signals for diagnostic assessment of insulating materials.A synchronization signal can be derived as well.It is suitable for both single shot as well as continuous PD monitoring.Although it must be customized on the basis of the shape and dimension of the test tap (to be provided by the Customer), many models are readily available for the most established transformer bushings. A list of the presently available models is reported below.Several thousands of hours of operation are a guarantee of reliability and accurate design.

  • High Voltage Power Supplies

    Guth GmbH

    The mains voltage (230V / 3 x 400V) is transformed, rectified and filtered by the HN series. The direct current output voltage is tuned by a variable transformer or regulated by a thyristor controller. With the HS and HV series the rectified mains voltage is supplied to a frequency converter, which produces a mid-frequency square wave voltage. This transformed, rectified and filtered alternating current produces the desired voltage as output, which is regulated by means of frequency variation or pulse width modulation. The equipment in the HV series supply, in addition to the high voltage output, up to 3 auxiliary outputs which can be used to supply e.g. heating, grid voltage or surge voltage.

  • 5VA Reference Supply, DC input

    PS5410C-16 - North Atlantic Industries

    The PS5410C-16 is a 5VA AC Reference Power Supply, available with many transformer isolated output voltages at different frequencies. Input power is either 12 VDC or 15 VDC. The standard 15 pin "D" connector simplifies interconnection to other equipment.

  • Precision Multirange Current Transformer

    P-2000 - The Eastern Specialty Company

    The Type P-2000-2 Knopp Precision Current Transformer is useful for high and low voltage work in the laboratory, shop and field for testing, measuring, and calibrating. The excellent accuracy and the One-to-One calibrating feature make it admirably suited as a standard for calibrating work.

  • Power Quality Analyzer

    PQM-700 - Sonel S.A.

    *power to the analyzer is supplied from tested mains (internal power supply) and is used in all types of networks from 64 V to 760 V, with particular emphasis on measurements at low voltage poles, due to the ease of connection,*has an independent power supply socket, especially suited for voltage measurements for transformers and DC circuits,built-in real-time clock.

Get Help